Top Saudi Conduit Suppliers & Distributors
- ITCC – International Tube & Conduit Company (factory lines EMT/IMC/RMC; wide local availability)
- AL SAYED CENTER (multi-branch retail)
- SAFETY LINE (conduit & accessories)
- SESCO – Saudi Electric Supply Co. (national distributor)
- AL SEWEDY / Elsewedy Electric (regional presence, partners in KSA)
- Al Baseela Trading (Eastern Province)
- Victory Electricals (retail counter & project supply)
Best Conduit for Saudi Projects : EMT, Flexible, Liquid-Tight & PVC Comparison
- EMT conduit (conduit emt / emt conduit): exposed indoor runs where alignment matters and bends are frequent
- Flexible electrical conduit: short offsets, machines, vibration
- Liquid tight flexible conduit: rooftops, washdown, pumps/HVAC — keep rating with liquid-tight straight/90° connectors
- PVC conduit (conduit pipe): underground or corrosive zones; choose Schedule 40 for general routing, Schedule 80 for higher impact protection
Conduits Prices & Part Numbers in Saudi Arabia ( EMT, Flexible, Liquid-Tight & PVC )
| Item | Example Part-No Style | Size / Spec | Price (SAR) |
|---|---|---|---|
| EMT conduit (multi-brand incl. ITCC) | EMT-ITCC-1IN-1P20-3050 | 1″ · ~1.20 mm wall · 3.05 m | 0–1,150 |
| EMT conduit (retail tag example) | EMT-ITCC-? | various | ~14.00–14.50 |
| Liquid-tight flexible conduit | LTFC-PVCJ-1IN-COIL | 1″ coil (PanFlex / United Electricals) | ~98–100 |
| LT flexible conduit (other stocked sizes) | LTFC-PVCJ-3P4-COIL | ¾″, 3/8″, 1½″, 4″ | size-dependent |
| PVC conduit (Schedule-40) | PVC-SCH40-20MM-STICK | 20 mm stick | from ~7.00–8.50 |
| PVC conduit (25 mm example) | PVC-SCH40-25MM-2P9M | 25 mm · 2.9 m | ~66.00 |
| CMP gland (E1FW-20S) | CMP-E1FW-20S-NP | Ex brass NP · SWA | from ~42.55 |
| CMP gland (CW-25 kit) | CMP-CW-25-KIT | SWA, industrial | on request |
| Copper terminal lugs (ring, pin, fork) | LUG-CU-16-M8 | 16 mm² · M8 | ~7.50–31.25 |

Typical Conduit Sizes Stocked in Saudi Arabia
- EMT: ½″, ¾″, 1″, 1¼″, 1½″, 2″, 2½″, 3″, 4″; sticks commonly 3.05 m; some items include color lines for system ID (fire/alarm, fiber).
- Liquid-tight flexible: 3/8″ to 4″, gray jacket; brands include United Electricals and PanFlex.
- PVC conduit: 20 mm, 25 mm, 32 mm and larger; confirm Schedule 40/80 and stick length on the quote.
Conduit Accessories for Saudi Sites : EMT Couplings, Liquid-Tight Connectors, Glands
- EMT fittings: set-screw for dry interiors; compression where damp or semi-outdoor.
- Liquid-tight connectors: order straight + 90° per equipment to maintain the ingress rating.
- CMP glands: E1FW for Ex/SWA; CW for industrial SWA terminations; use authorized KSA channels for traceability.
- Terminal lugs: specify cross-section and stud size (e.g., 50 mm²/M10) to avoid rework at panels.
RFQ Checklist for Saudi Buyers (Keep Quotes Accurate)
- Include the part-no style in the BOQ (type–brand–size–wall–length).
- State the environment (indoor/outdoor/washdown/UV).
- For liquid-tight flexible conduit, list quantities of straight/90° connectors.
- For PVC underground, specify Schedule and pull-rope if required.
- Attach a plan extract or sketch with conduit runs highlighted.
Micro-FAQ For Conduits
- Which conduit for rooftop pumps/HVAC?
Liquid tight flexible conduit with matched LT connectors to keep the seal in sun and washdown. - How to force exact spec in quotes?
Use the BOQ coding method so size, wall, and length are fixed in the part code. - Do I need Schedule 80 for PVC?
Use Schedule 80 when the run faces higher impact risk; otherwise Schedule 40 is common for general routing.